Acoustic Pipe Insulation for Gas Flow Noise

Acoustic Pipe insulation with ArmaSound Industrial system in the metering station of Natural Gas (NG) pipeline (50 meter of 36”inch pipe) Sound Pressure Level before Installation : 110 dB(A) Provide noise survey & select the solution for the noise control. Provide installation training and supervise the installation at the job site Sound Pressure Level after installation : 85 dB(A) Sound Pressure Level at behind the fence (10 meter from noise source) : 66 dB(A) Criteria of noise reduction : Reduce noise at the outside the fence below 70 dB(A)

Case Study in the metering station of Power Plant

Read more

Sound Proof for the Gas Comressor

Three Gas Compressors to supply to the fuel to the Gas turbine generate loud noise to outside area which is about 14 meter from the fence. Acoustic enclosure is needed to covered the noise together with ArmaSound Super Silence as the ceiling and wall lining insider the enclosure. The ArmaSound was covered with the metal perforated with 50% opening to prevent it falling down from the ceiling. Noise level at the compressor is ranged from 98 -100 dB(A), when it is 2 compressor operating maximum together. At the 1 meter from the enclsure surface, the noise can be reduced down to 65 -70 dB(A) around the enclosure.

How Gas Compressor make noise

Read more

Non Metallic Cladding in Pharmaceutical Factory

Mould Mildew and bacteria can penetrate to the pipe insulation via the sharp metallic cladding. The engineer find the way to solve this problem, Therefore, the polymeric with shinny surface like ArmaChek Silver is the best solution for this application. it provides aesthetic surface, and also not damage when the mechanic impact to its surface. This is suitable for the Pharmaceutical factories, Food Factories, where the hygienic is required.

ArmaChek Silver The Non metallic Cladding choice for the pipe insulation

Read more

My pipe insulation is starting to leak in 3 months

One interesting case study from the food manufacturing where the cold system is 24/7 operating. The mechanical engineer found the water droplet at the pipe support and pipe hanger at the pipe work above their ceiling. Checking the pipe insulation system, it was found the problem of the missing install and select the right pipe support or pipe hanger insulation. Wow! what should I do next. Should I need to change the whole pipe support. It is a nightmare.

Solution of Pipe support insulation

Read more